Pro AV Catalog
Manufacturers
PRODUCT CATEGORIES
Matching Keywords
Model Numbers
Request Quote
All Products
Vertical Compact Loudspeaker Array for 70/100V Distributed Systems
Model: ADC-V90 MARK II
- Unit shall be constructed as a line-array of six 4” full-range loudspeakers, equipped with moisture resistant diaphragms and shall be designed for use in 100 V/70 V professional audio installations
- Unit is intended for use in both public address and voice alarm systems and shall be compliant with EN 54-24
- Unit shall be suitable for both indoor and outdoor use and therefore shall be compliant with the environmental requirements of EN 54-24 for both types A & B
- Additional internal fuse shall be used to protect the unit from excess current
- All connectors, fuses and switches shall be grouped together inside the unit and shall be accessible from a cover plate on the front of the unit
Compare
Project List
Product Info
Tech Specs
Documents
The unit shall be constructed as a line-array of six 4” full-range loudspeakers, equipped with moisture resistant diaphragms and shall be designed for use in 100 V/70 V professional audio installations. The unit is intended for use in both public address and voice alarm systems and shall be compliant with EN 54-24. The unit shall be suitable for both indoor and outdoor use and therefore shall be compliant with the environmental requirements of EN 54-24 for both types A & B.
The audio signal shall be connected to a ceramic terminal block. A thermal fuse shall be included in the internal audio path to disconnect the unit from the 100 V/ 70V line should the unit be exposed to extreme heat and/or fire. An additional internal fuse shall be used to protect the unit from excess current. All connectors, fuses and switches shall be grouped together inside the unit and shall be accessible from a cover plate on the front of the unit. A gland shall be provided for cable entry on the rear of the unit.
A LED shall be fitted to the loudspeaker baffle which illuminates on detection of a constant high frequency pilot-tone, which shall indicate that the unit is properly connected to the 100 V/70 V line. The LED shall be visible with the grill installed.
The enclosure shall be constructed of steel finished with an epoxy coating. At the back side of the enclosure a total of two bracket attachment points shall be provided (located near the outer ends). The protective front shall consist of a perforated steel grill which can be clicked onto four snap-in studs mounted on the enclosure. For added security grill security screws shall be provided to lock the steel grill in place.
The audio signal shall be connected to a ceramic terminal block. A thermal fuse shall be included in the internal audio path to disconnect the unit from the 100 V/ 70V line should the unit be exposed to extreme heat and/or fire. An additional internal fuse shall be used to protect the unit from excess current. All connectors, fuses and switches shall be grouped together inside the unit and shall be accessible from a cover plate on the front of the unit. A gland shall be provided for cable entry on the rear of the unit.
A LED shall be fitted to the loudspeaker baffle which illuminates on detection of a constant high frequency pilot-tone, which shall indicate that the unit is properly connected to the 100 V/70 V line. The LED shall be visible with the grill installed.
The enclosure shall be constructed of steel finished with an epoxy coating. At the back side of the enclosure a total of two bracket attachment points shall be provided (located near the outer ends). The protective front shall consist of a perforated steel grill which can be clicked onto four snap-in studs mounted on the enclosure. For added security grill security screws shall be provided to lock the steel grill in place.
- Unit shall be constructed as a line-array of six 4” full-range loudspeakers, equipped with moisture resistant diaphragms and shall be designed for use in 100 V/70 V professional audio installations
- Unit is intended for use in both public address and voice alarm systems and shall be compliant with EN 54-24
- Unit shall be suitable for both indoor and outdoor use and therefore shall be compliant with the environmental requirements of EN 54-24 for both types A & B
- Additional internal fuse shall be used to protect the unit from excess current
- All connectors, fuses and switches shall be grouped together inside the unit and shall be accessible from a cover plate on the front of the unit
- LED shall be fitted to the loudspeaker baffle which illuminates on detection of a constant high frequency pilot-tone, which shall indicate that the unit is properly connected to the 100 V/70 V line
- Enclosure shall be constructed of steel finished with an epoxy coating
- Horizontal Symmetry - Yes
- Loudspeaker Mount Type - Ceiling
- Vertical Symmetry - Yes
- Loudspeaker Setup - Rigged
- Spec Sheet available - Yes
- Construction: Steel
- Coverage Horizontal: 130 degrees
- Coverage Vertical: 30 degrees
- Maximum SPL (Sound Pressure Level): 100 dB
- Sensitivity: 80 dB
- Depth: 3.62 in
- Height: 34.06 in
- Width: 5.28 in
- Product Weight: 22.05 lbs
Loudspeaker Array
1048 kb
- Data Sheet
Project List
Request Quote
Suggested Products
Thank you!
Someone will be in touch with you shortly.
Contact McCann Systems
close
McCann Systems
290 Fernwood Avenue
Edison, NJ 08837
USA
1-888-414-3806
www.mccannsystems.com
Contact in regards to this product:
JBL Professional
Model: ADC-V90 MARK II
Request more information from a dealer near you
close
Request more information from a dealer near you